Manufacturer’s Description

 

Kane 455 CPA1 Flue Gas Analyser Kit

 

KANE 455 Infra-red flue gas analyser has an easy to use rotary switch. The user can view, and log combustion tests including CO/CO2 ratio, pressure, tightness, temperature and room CO tests.

 

Features high accuracy and stability of pressure readings, and complete tasks such as checking the air/fuel ratio on high efficiency boilers and measuring flue draughts.

 

Features:

 

 

    • Easy to use rotary switch.

 

    • Multi-fuel: Natural Gas, Propane, Butane LPG & Light Oils.

 

    • Protective rubber sleeve with integral magnet for “hands free” use.

 

    • High accuracy manometer.

 

    • Differential thermometer.

 

    • Separate reports for:

 

    • Combustion

 

    • Pressure

 

    • Let-by and Tightness

 

    • CO build up

 

    • Battery life typically 12+ hours.

 

  • 5 year extended warranty if serviced annually by Kane

 

Designed to meet BS EN 50379.

MULTIFEED_END_22_

MULTIFEED_START_23_

Technical specification

 

Flue Temperature

 

 

    • Resolution: 0.1°C

 

    • Accuracy:  ± 2.0°C, ± 1% reading

 

  • Range: 0-600°C

 

Inlet Temperature (Internal sensor)

 

 

    • Resolution: 0.1°C

 

    • Accuracy:  ± 1°C

 

  • Range: 0-50°C

 

Inlet Temperature (External sensor)

 

 

    • Resolution: 0.1°C

 

    • Accuracy: ± 2°C, ± 1% reading

 

  • Range: 0-600°C

 

Oxygen

 

 

    • Resolution:  0.1%

 

    • Accuracy: ± 0.3%

 

  • Range: 0-21%

 

Carbon Monoxide

 

 

    • Resolution: 1ppm

 

    • Accuracy: ±5ppm <100ppm, ± 5% reading >100ppm

 

  • Range: 0-1,000ppm, 4000 ppm max for 15 minutes

 

Carbon Dioxide

 

 

    • Resolution: 0.1%

 

    • Accuracy: ± 0.2% reading

 

  • Range: 0-20%

 

Efficiency

 

 

    • Resolution: 0.1%

 

  • Range: 0-99.9%

 

Excess Air

 

 

    • Resolution: 0.1%

 

  • Range: 0-250%

 

CO/CO2 ratio

 

 

    • Resolution: 0.0001

 

  • Range: 0-0.9999

 

Pressure nominal range 80mbar

 

 

    • Resolution: 0.001mbar, 24.999 bar, then 0.01mbar

 

    • Accuracy: ±0.005mbar, ±0.03mbar, ±3% of reading

 

  • Range: ±0.2mbar, ±1mbar, ±80mbar

 

Pre-programmed Fuels – Natural gas, Propane, Butane, LPG, Light Oils (28/35 sec), Wood Pellets

 

Storage Capacity:

 

 

    • 99 Combustion tests

 

    • 20 Pressure tests

 

    • 20 Tightness tests

 

    • 20 Temperature tests

 

  • 20 Room CO tests

 

Ambient Operating Range

 

0oC to +40oC     10% to 90% RH non-condensing

 

Battery Type / Life

 

4 AA cells>8 hours using Alkaline AA cells

 

Chargers (optional)

 

220v charger, for NiMH batteries only

 

12v in vehicle charger, for NiMH batteries only

 

 

 

Dimensions

 

Weight: 0.8kg handset with protective cover

 

Handset: 200 x 45 x 90mm

 

 

 

Probe

 

300mm long including handle. 6mm diameter x 240mm long stainless steel shaft with 3m long neoprene hose.  Type K thermocouple

MULTIFEED_END_23_

MULTIFEED_START_24_

What you get

 

 

    • 455 flue gas analyser,

 

    • KMCP2 probe,

 

    • 4 x NiMH rechargeable batteries, battery charger,

 

    • 2 x pressure fittings,

 

    • 1 x pressure hose,

 

    • KMIRP infra red printer,

 

    • GLD450 Gas leak detector,

 

    • 1 x KAL1 air/liquid temperature probe,

 

    • 2 x KPCP clamp-on pipe probes,

 

    • Appliance sampling probe kit,

 

    • Manuals, training DVD,

 

    • Calibration Certificates

 

  • Carry case.

MULTIFEED_END_24_

MULTIFEED_START_25_

  • DEALS AVAILABLE: 10

 

  • DEALS DONE: 3

 

  • DEALS LEFT: 7

 

  • Deal Ends
      •   22/03/2012
    •   11:00 AM

 

  • Delivery
    • 4 – 5 days from end

 

  • Deal status: Open

MULTIFEED_END_25_

 

Always check My Mate Mark for current group buying deals.

This entry was posted in Power Tools and tagged , . Bookmark the permalink.

Comments are closed.